sim: Adding support for power models
[gem5.git] / src / sim / VoltageDomain.py
1 # Copyright (c) 2012 ARM Limited
2 # All rights reserved.
3 #
4 # The license below extends only to copyright in the software and shall
5 # not be construed as granting a license to any other intellectual
6 # property including but not limited to intellectual property relating
7 # to a hardware implementation of the functionality of the software
8 # licensed hereunder. You may use the software subject to the license
9 # terms below provided that you ensure that this notice is replicated
10 # unmodified and in its entirety in all distributions of the software,
11 # modified or unmodified, in source code or in binary form.
12 #
13 # Redistribution and use in source and binary forms, with or without
14 # modification, are permitted provided that the following conditions are
15 # met: redistributions of source code must retain the above copyright
16 # notice, this list of conditions and the following disclaimer;
17 # redistributions in binary form must reproduce the above copyright
18 # notice, this list of conditions and the following disclaimer in the
19 # documentation and/or other materials provided with the distribution;
20 # neither the name of the copyright holders nor the names of its
21 # contributors may be used to endorse or promote products derived from
22 # this software without specific prior written permission.
23 #
24 # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
25 # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
26 # LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
27 # A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
28 # OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
29 # SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
30 # LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
31 # DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
32 # THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
33 # (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
34 # OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
35 #
36 # Authors: Vasileios Spiliopoulos
37 # Akash Bagdia
38
39 from m5.SimObject import SimObject
40 from m5.params import *
41
42 class VoltageDomain(SimObject):
43 type = 'VoltageDomain'
44 cxx_header = "sim/voltage_domain.hh"
45
46 # Single or list of voltages for the voltage domain. If only a single
47 # voltage is specified, it is used for all different frequencies.
48 # Otherwise, the number of specified voltges and frequencies in the clock
49 # domain (src/sim/ClockDomain.py) must match. Voltages must be specified in
50 # descending order. We use a default voltage of 1V to avoid forcing users to
51 # set it even if they are not interested in using the functionality
52 voltage = VectorParam.Voltage('1V', "Operational voltage(s)")