Gallium: fix for conform test
The following construction in util_surface_copy() in
gallium/auxiliary/util/u_rect.c, introduced in commit
d177c9ddda2c452cf7d6696d89cf4458ef986f98, incorrectly inverts
the Y coordinate in the last parameter to pipe_copy_rect().
/* If do_flip, invert src_y position and pass negative src stride
*/
pipe_copy_rect(dst_map,
&dst->block,
dst->stride,
dst_x, dst_y,
w, h,
src_map,
do_flip ? -(int) src->stride : src->stride,
src_x,
do_flip ? w - src_y : src_y);
The intention is to start at the last Y coordinate line and move
backwards, in the case of a flip; in that case, the correct
calculation is "src_y + h - 1", not "w - src_y".
This fixes a Gallium assertion failure in the conformance tests:
u_rect.c:65:pipe_copy_rect: Assertion `src_y >= 0' failed.
debug_get_bool_option: GALLIUM_ABORT_ON_ASSERT = TRUE
Trace/breakpoint trap