* config/tc-i386.c: Formatting fixes, add missing space in error
authorAlan Modra <amodra@gmail.com>
Sun, 28 Apr 2002 12:19:46 +0000 (12:19 +0000)
committerAlan Modra <amodra@gmail.com>
Sun, 28 Apr 2002 12:19:46 +0000 (12:19 +0000)
message.

gas/ChangeLog
gas/config/tc-i386.c

index 8e498885faaeb0595da6919c4bf4a007b59417b9..685dd30955accfff014dca90a395cc63a48dfe8a 100644 (file)
@@ -1,3 +1,8 @@
+2002-04-28  Alan Modra  <amodra@bigpond.net.au>
+
+       * config/tc-i386.c: Formatting fixes, add missing space in error
+       message.
+
 2002-04-24  Christian Groessler <chris@groessler.org>
 
        * config/tc-z8k.c (build_bytes): Add support for new cases:
@@ -38,7 +43,7 @@
        * config/tc-s390.c (tc_s390_fix_adjustable): Prevent adjustments to
        symbols in merge sections.
 
-2002-04-16  Alan Modra  <alan@weed.local>
+2002-04-16  Alan Modra  <amodra@bigpond.net.au>
 
        * as.c (main): Don't reference _bfd_chunksize.
 
index ec1da5c6b34ec48df2edf0fff385d050c891aef7..35bdb94e1db2cb7b82195c15be74d4c2405f6e1a 100644 (file)
@@ -2208,15 +2208,15 @@ process_suffix ()
 
   /* For movzx and movsx, need to check the register type.  */
   if (intel_syntax
-      && (i.tm.base_opcode == 0xfb6 || i.tm.base_opcode == 0xfbe))
-    if (i.suffix && i.suffix == BYTE_MNEM_SUFFIX)
-      {
-       unsigned int prefix = DATA_PREFIX_OPCODE;
+      && (i.tm.base_opcode == 0xfb6 || i.tm.base_opcode == 0xfbe)
+      && i.suffix == BYTE_MNEM_SUFFIX)
+    {
+      unsigned int prefix = DATA_PREFIX_OPCODE;
 
-       if ((i.op[1].regs->reg_type & Reg16) != 0)
-         if (!add_prefix (prefix))
-           return 0;
-      }
+      if ((i.op[1].regs->reg_type & Reg16) != 0)
+       if (!add_prefix (prefix))
+         return 0;
+    }
 
   if (i.suffix && i.suffix != BYTE_MNEM_SUFFIX)
     {
@@ -2228,6 +2228,7 @@ process_suffix ()
          else
            i.tm.base_opcode |= 1;
        }
+
       /* Now select between word & dword operations via the operand
         size prefix, except for instructions that will ignore this
         prefix anyway.  */
@@ -2309,7 +2310,7 @@ check_byte_reg ()
          if (flag_code == CODE_64BIT
              && (i.tm.operand_types[op] & InOutPortReg) == 0)
            {
-             as_bad (_("Incorrect register `%%%s' used with`%c' suffix"),
+             as_bad (_("Incorrect register `%%%s' used with `%c' suffix"),
                      i.op[op].regs->reg_name,
                      i.suffix);
              return 0;
@@ -2368,7 +2369,7 @@ check_long_reg ()
           lowering is more complicated.  */
        if (flag_code == CODE_64BIT)
          {
-           as_bad (_("Incorrect register `%%%s' used with`%c' suffix"),
+           as_bad (_("Incorrect register `%%%s' used with `%c' suffix"),
                    i.op[op].regs->reg_name,
                    i.suffix);
            return 0;
@@ -2385,7 +2386,7 @@ check_long_reg ()
     else if ((i.types[op] & Reg64) != 0
             && (i.tm.operand_types[op] & (Reg32 | Acc)) != 0)
       {
-       as_bad (_("Incorrect register `%%%s' used with`%c' suffix"),
+       as_bad (_("Incorrect register `%%%s' used with `%c' suffix"),
                i.op[op].regs->reg_name,
                i.suffix);
        return 0;
@@ -2417,7 +2418,7 @@ check_qword_reg ()
       {
        /* Prohibit these changes in the 64bit mode, since the
           lowering is more complicated.  */
-       as_bad (_("Incorrect register `%%%s' used with`%c' suffix"),
+       as_bad (_("Incorrect register `%%%s' used with `%c' suffix"),
                i.op[op].regs->reg_name,
                i.suffix);
        return 0;
@@ -2450,7 +2451,7 @@ check_word_reg ()
           lowering is more complicated.  */
        if (flag_code == CODE_64BIT)
          {
-           as_bad (_("Incorrect register `%%%s' used with`%c' suffix"),
+           as_bad (_("Incorrect register `%%%s' used with `%c' suffix"),
                    i.op[op].regs->reg_name,
                    i.suffix);
            return 0;