The BusyBox watchdog application supports reset periods specified in
milliseconds. The Buildroot package will only allow an integer reset period,
which prevents the use of the required "ms" suffix. Change the watchdog period
configuration item to a string, to allow the use of the "ms" suffix.
Signed-off-by: Simon Dawson <spdawson@gmail.com>
Signed-off-by: Peter Korsgaard <jacmet@sunsite.dk>
if BR2_PACKAGE_BUSYBOX_WATCHDOG
config BR2_PACKAGE_BUSYBOX_WATCHDOG_PERIOD
- int "Delay between reset"
+ string "Delay between reset"
default "5"
help
Select the number of seconds between each
reset of the watchdog (default 5)
+ Use ms suffix to specify milliseconds (e.g. 500ms)
+
endif
endif
[ -f $(TARGET_DIR)/etc/init.d/S15watchdog ] || \
install -D -m 0755 package/busybox/S15watchdog \
$(TARGET_DIR)/etc/init.d/S15watchdog && \
- sed -i s/PERIOD/$(BR2_PACKAGE_BUSYBOX_WATCHDOG_PERIOD)/ \
+ sed -i s/PERIOD/$(call qstrip,$(BR2_PACKAGE_BUSYBOX_WATCHDOG_PERIOD))/ \
$(TARGET_DIR)/etc/init.d/S15watchdog
endef
endif