The actual data storred is in float, UNORM24, or UNORM16 depending on the
actual depth format.
Signed-off-by: Jason Ekstrand <jason@jlekstrand.net>
Reviewed-by: Kenneth Graunke <kenneth@whitecape.org>
<field name="3D Command Sub Opcode" start="16" end="23" type="uint" default="16"/>
<field name="Depth Clear Value Valid" start="15" end="15" type="bool"/>
<field name="DWord Length" start="0" end="7" type="uint" default="0"/>
- <field name="Depth Clear Value" start="32" end="63" type="float"/>
+ <field name="Depth Clear Value" start="32" end="63" type="uint"/>
</instruction>
<instruction name="3DSTATE_CLIP" bias="2" length="4">