config, arm, power: Example to report the power for the L2 Cache
authorSherif Elhabbal <elhabbalsherif@gmail.com>
Fri, 14 Sep 2018 15:10:24 +0000 (17:10 +0200)
committerSherif Elhabbal <elhabbalsherif@gmail.com>
Mon, 17 Sep 2018 17:59:34 +0000 (17:59 +0000)
This patch add an example to demonstrate how to report the power for the L2
Cache of the big cluster separately ,it decouples the L2 contributions from
the CPU power equation

Signed-off-by: Sherif Elhabbal <elhabbalsherif@gmail.com>
Change-Id: Idde43c8bcb10df9d44d20282eaf21ce87a9d3f58
Reviewed-on: https://gem5-review.googlesource.com/12684
Reviewed-by: Jason Lowe-Power <jason@lowepower.com>
Reviewed-by: Anouk Van Laer <anouk.vanlaer@arm.com>
Maintainer: Jason Lowe-Power <jason@lowepower.com>

configs/example/arm/fs_power.py

index b27455f13978dfb138fcd7a5c51a41ca9edd6776..7b92c8db8dbd105a283359739d64eea4ca55a2b6 100644 (file)
@@ -69,6 +69,25 @@ class CpuPowerModel(PowerModel):
         CpuPowerOff(), # OFF
     ]
 
+class L2PowerOn(MathExprPowerModel):
+    # Example to report l2 Cache overall_accesses
+    # The estimated power is converted to Watt and will vary based on the size of the cache
+    dyn = "overall_accesses*0.000018000"
+    st = "(voltage * 3)/10"
+
+class L2PowerOff(MathExprPowerModel):
+    dyn = "0"
+    st = "0"
+
+class L2PowerModel(PowerModel):
+    # Choose a power model for every power state
+    pm = [
+        L2PowerOn(), # ON
+        L2PowerOff(), # CLK_GATED
+        L2PowerOff(), # SRAM_RETENTION
+        L2PowerOff(), # OFF
+    ]
+
 
 def main():
     parser = argparse.ArgumentParser(
@@ -90,6 +109,14 @@ def main():
         cpu.default_p_state = "ON"
         cpu.power_model = CpuPowerModel()
 
+    # Example power model for the L2 Cache of the bigCluster
+    for l2 in root.system.bigCluster.l2.descendants():
+        if not isinstance(l2, m5.objects.Cache):
+            continue
+
+        l2.default_p_state = "ON"
+        l2.power_model = L2PowerModel()
+
     bL.instantiate(options)
 
     print("*" * 70)