void init_execution_control_state (struct execution_control_state *ecs);
+static void handle_step_into_function (struct execution_control_state *ecs,
+ CORE_ADDR real_stop_pc);
void handle_inferior_event (struct execution_control_state *ecs);
static void check_sigtramp2 (struct execution_control_state *ecs);
return PC_IN_SIGTRAMP (pc, name);
}
+/* Handle the inferior event in the cases when we just stepped
+ into a function. */
+
+static void
+handle_step_into_function (struct execution_control_state *ecs,
+ CORE_ADDR real_stop_pc)
+{
+ if ((step_over_calls == STEP_OVER_NONE)
+ || ((step_range_end == 1)
+ && in_prologue (prev_pc, ecs->stop_func_start)))
+ {
+ /* I presume that step_over_calls is only 0 when we're
+ supposed to be stepping at the assembly language level
+ ("stepi"). Just stop. */
+ /* Also, maybe we just did a "nexti" inside a prolog,
+ so we thought it was a subroutine call but it was not.
+ Stop as well. FENN */
+ stop_step = 1;
+ print_stop_reason (END_STEPPING_RANGE, 0);
+ stop_stepping (ecs);
+ return;
+ }
+
+ if (step_over_calls == STEP_OVER_ALL || IGNORE_HELPER_CALL (stop_pc))
+ {
+ /* We're doing a "next". */
+
+ if (pc_in_sigtramp (stop_pc)
+ && frame_id_inner (step_frame_id,
+ frame_id_build (read_sp (), 0)))
+ /* We stepped out of a signal handler, and into its
+ calling trampoline. This is misdetected as a
+ subroutine call, but stepping over the signal
+ trampoline isn't such a bad idea. In order to do that,
+ we have to ignore the value in step_frame_id, since
+ that doesn't represent the frame that'll reach when we
+ return from the signal trampoline. Otherwise we'll
+ probably continue to the end of the program. */
+ step_frame_id = null_frame_id;
+
+ step_over_function (ecs);
+ keep_going (ecs);
+ return;
+ }
+
+ /* If we are in a function call trampoline (a stub between
+ the calling routine and the real function), locate the real
+ function. That's what tells us (a) whether we want to step
+ into it at all, and (b) what prologue we want to run to
+ the end of, if we do step into it. */
+ real_stop_pc = skip_language_trampoline (stop_pc);
+ if (real_stop_pc == 0)
+ real_stop_pc = SKIP_TRAMPOLINE_CODE (stop_pc);
+ if (real_stop_pc != 0)
+ ecs->stop_func_start = real_stop_pc;
+
+ /* If we have line number information for the function we
+ are thinking of stepping into, step into it.
+
+ If there are several symtabs at that PC (e.g. with include
+ files), just want to know whether *any* of them have line
+ numbers. find_pc_line handles this. */
+ {
+ struct symtab_and_line tmp_sal;
+
+ tmp_sal = find_pc_line (ecs->stop_func_start, 0);
+ if (tmp_sal.line != 0)
+ {
+ step_into_function (ecs);
+ return;
+ }
+ }
+
+ /* If we have no line number and the step-stop-if-no-debug
+ is set, we stop the step so that the user has a chance to
+ switch in assembly mode. */
+ if (step_over_calls == STEP_OVER_UNDEBUGGABLE && step_stop_if_no_debug)
+ {
+ stop_step = 1;
+ print_stop_reason (END_STEPPING_RANGE, 0);
+ stop_stepping (ecs);
+ return;
+ }
+
+ step_over_function (ecs);
+ keep_going (ecs);
+ return;
+}
/* Given an execution control state that has been freshly filled in
by an event from the inferior, figure out what it means and take
|| ecs->stop_func_name == 0)
{
/* It's a subroutine call. */
-
- if ((step_over_calls == STEP_OVER_NONE)
- || ((step_range_end == 1)
- && in_prologue (prev_pc, ecs->stop_func_start)))
- {
- /* I presume that step_over_calls is only 0 when we're
- supposed to be stepping at the assembly language level
- ("stepi"). Just stop. */
- /* Also, maybe we just did a "nexti" inside a prolog,
- so we thought it was a subroutine call but it was not.
- Stop as well. FENN */
- stop_step = 1;
- print_stop_reason (END_STEPPING_RANGE, 0);
- stop_stepping (ecs);
- return;
- }
-
- if (step_over_calls == STEP_OVER_ALL || IGNORE_HELPER_CALL (stop_pc))
- {
- /* We're doing a "next". */
-
- if (pc_in_sigtramp (stop_pc)
- && frame_id_inner (step_frame_id,
- frame_id_build (read_sp (), 0)))
- /* We stepped out of a signal handler, and into its
- calling trampoline. This is misdetected as a
- subroutine call, but stepping over the signal
- trampoline isn't such a bad idea. In order to do that,
- we have to ignore the value in step_frame_id, since
- that doesn't represent the frame that'll reach when we
- return from the signal trampoline. Otherwise we'll
- probably continue to the end of the program. */
- step_frame_id = null_frame_id;
-
- step_over_function (ecs);
- keep_going (ecs);
- return;
- }
-
- /* If we are in a function call trampoline (a stub between
- the calling routine and the real function), locate the real
- function. That's what tells us (a) whether we want to step
- into it at all, and (b) what prologue we want to run to
- the end of, if we do step into it. */
- real_stop_pc = skip_language_trampoline (stop_pc);
- if (real_stop_pc == 0)
- real_stop_pc = SKIP_TRAMPOLINE_CODE (stop_pc);
- if (real_stop_pc != 0)
- ecs->stop_func_start = real_stop_pc;
-
- /* If we have line number information for the function we
- are thinking of stepping into, step into it.
-
- If there are several symtabs at that PC (e.g. with include
- files), just want to know whether *any* of them have line
- numbers. find_pc_line handles this. */
- {
- struct symtab_and_line tmp_sal;
-
- tmp_sal = find_pc_line (ecs->stop_func_start, 0);
- if (tmp_sal.line != 0)
- {
- step_into_function (ecs);
- return;
- }
- }
-
- /* If we have no line number and the step-stop-if-no-debug
- is set, we stop the step so that the user has a chance to
- switch in assembly mode. */
- if (step_over_calls == STEP_OVER_UNDEBUGGABLE && step_stop_if_no_debug)
- {
- stop_step = 1;
- print_stop_reason (END_STEPPING_RANGE, 0);
- stop_stepping (ecs);
- return;
- }
-
- step_over_function (ecs);
- keep_going (ecs);
+ handle_step_into_function (ecs, real_stop_pc);
return;
-
}
/* We've wandered out of the step range. */