return m
+ # The synchronizer implementations below apply the ASYNC_REG attribute. This attribute
+ # prevents inference of shift registers from synchronizer FFs, and constraints the FFs
+ # to be placed as close as possible, ideally in one CLB. This attribute only affects
+ # the synchronizer FFs themselves.
+
def get_ff_sync(self, ff_sync):
if ff_sync._max_input_delay is not None:
raise NotImplementedError("Platform {!r} does not support constraining input delay "