i965: Use 64-bit writes for occlusion queries.
authorKenneth Graunke <kenneth@whitecape.org>
Tue, 7 Aug 2012 17:17:04 +0000 (10:17 -0700)
committerKenneth Graunke <kenneth@whitecape.org>
Wed, 8 Aug 2012 16:24:23 +0000 (09:24 -0700)
The hardware seems to use the length of the PIPE_CONTROL command to
indicate whether the write is 64-bits or 32-bits.  Which makes sense
for immediate writes.

Daniel discovered this by writing a pattern into the query object bo
and noticing that the high 32-bits were left intact, even on those
pipe control writes that seemingly worked.

Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Signed-off-by: Kenneth Graunke <kenneth@whitecape.org>
Reviewed-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Reviewed-by: Eric Anholt <eric@anholt.net>
src/mesa/drivers/dri/i965/brw_queryobj.c

index d45edc18d942947414a374e5c9656312e2c6beec..1e03d083dac3fe3377f11a3e0ffb07de4f9a7dfa 100644 (file)
@@ -91,7 +91,7 @@ static void
 write_depth_count(struct intel_context *intel, drm_intel_bo *query_bo, int idx)
 {
    if (intel->gen >= 6) {
-      BEGIN_BATCH(8);
+      BEGIN_BATCH(9);
 
       /* workaround: CS stall required before depth stall. */
       OUT_BATCH(_3DSTATE_PIPE_CONTROL | (4 - 2));
@@ -99,7 +99,7 @@ write_depth_count(struct intel_context *intel, drm_intel_bo *query_bo, int idx)
       OUT_BATCH(0); /* write address */
       OUT_BATCH(0); /* write data */
 
-      OUT_BATCH(_3DSTATE_PIPE_CONTROL | (4 - 2));
+      OUT_BATCH(_3DSTATE_PIPE_CONTROL | (5 - 2));
       OUT_BATCH(PIPE_CONTROL_DEPTH_STALL |
                 PIPE_CONTROL_WRITE_DEPTH_COUNT);
       OUT_RELOC(query_bo,
@@ -107,6 +107,7 @@ write_depth_count(struct intel_context *intel, drm_intel_bo *query_bo, int idx)
                 PIPE_CONTROL_GLOBAL_GTT_WRITE |
                 (idx * sizeof(uint64_t)));
       OUT_BATCH(0);
+      OUT_BATCH(0);
       ADVANCE_BATCH();
    } else {
       BEGIN_BATCH(4);