h8300-protos.h: Fix formatting.
authorKazu Hirata <kazu@hxi.com>
Fri, 1 Mar 2002 09:14:08 +0000 (09:14 +0000)
committerKazu Hirata <kazu@gcc.gnu.org>
Fri, 1 Mar 2002 09:14:08 +0000 (09:14 +0000)
* config/h8300/h8300-protos.h: Fix formatting.
* config/h8300/h8300.c: Likewise.
* config/h8300/h8300.h: Likewise.

From-SVN: r50192

gcc/ChangeLog
gcc/config/h8300/h8300-protos.h
gcc/config/h8300/h8300.c
gcc/config/h8300/h8300.h

index d8e0b1f89adc7c3a4ab737e407f8b13ce541d365..9bdcf0dc3f8e393e81c7fe1b5217b5aceb07b963 100644 (file)
@@ -1,3 +1,9 @@
+2002-03-01  Kazu Hirata  <kazu@hxi.com>
+
+       * config/h8300/h8300-protos.h: Fix formatting.
+       * config/h8300/h8300.c: Likewise.
+       * config/h8300/h8300.h: Likewise.
+
 2002-03-01  Kazu Hirata  <kazu@hxi.com>
 
        * config/h8300/h8300.c (print_operand): Support 16-bit
index e930d5ec0dd04de3bdb1312ce6bc4315a5a0143e..ff31530dec981d3883624862aa21bbda78621032 100644 (file)
@@ -1,5 +1,5 @@
-/* Definitions of target machine for GNU compiler. 
-   Hitachi H8/300 version generating coff 
+/* Definitions of target machine for GNU compiler.
+   Hitachi H8/300 version generating coff
    Copyright (C) 2000 Free SoftwareFoundation, Inc.
    Contributed by Steve Chamberlain (sac@cygnus.com),
    Jim Wilson (wilson@cygnus.com), and Doug Evans (dje@cygnus.com).
index b8e7d98cf0e31b1c25935b642378b432461c5493..7a77cc8a024374d4471c408e6c5909489b94ea67 100644 (file)
@@ -270,7 +270,7 @@ pop (file, rn)
   fprintf (file, "\t%s\t%s\n", h8_pop_op, h8_reg_names[rn]);
 }
 
-/* This is what the stack looks like after the prolog of 
+/* This is what the stack looks like after the prolog of
    a function with a frame has been set up:
 
    <args>
@@ -1842,7 +1842,7 @@ compute_logical_op_cc (mode, operands)
    Below, a trailing '*' after the shift count indicates the "best"
    mode isn't implemented.  We only describe SHIFT_SPECIAL cases to
    simplify the table.  For other cases, refer to shift_alg_[qhs]i.
-   
+
    H8/300 QImode shifts
    7      - ASHIFTRT: shll, subx (propagate carry bit to all bits)
 
@@ -2588,7 +2588,7 @@ get_shift_alg (shift_type, shift_mode, count, info)
       else if (TARGET_H8300 && 24 <= count && count <= 28)
        {
          info->remainder = count - 24;
+
          switch (shift_type)
            {
            case SHIFT_ASHIFT:
index 6175d310f306cb9abb17ba96ee787c4ff2df0368..c5852f54c6d671729e5e5b2c7f76990c02f2dec6 100644 (file)
@@ -1,5 +1,5 @@
-/* Definitions of target machine for GNU compiler. 
-   Hitachi H8/300 version generating coff 
+/* Definitions of target machine for GNU compiler.
+   Hitachi H8/300 version generating coff
    Copyright (C) 1992, 1993, 1994, 1995, 1996, 1996, 1997, 1998, 1999,
    2000, 2001, 2002 Free Software Foundation, Inc.
    Contributed by Steve Chamberlain (sac@cygnus.com),
@@ -171,7 +171,7 @@ extern int target_flags;
 /* Define this if addresses of constant functions
    shouldn't be put through pseudo regs where they can be cse'd.
    Desirable on machines where ordinary constants are expensive
-   but a CALL with constant address is cheap. 
+   but a CALL with constant address is cheap.
 
    Calls through a register are cheaper than calls to named
    functions; however, the register pressure this causes makes
@@ -194,7 +194,7 @@ extern int target_flags;
 #define BYTES_BIG_ENDIAN 1
 
 /* Define this if most significant word of a multiword number is lowest
-   numbered.  
+   numbered.
    This is true on an H8/300 (actually we can make it up, but we choose to
    be consistent).  */
 #define WORDS_BIG_ENDIAN 1
@@ -263,7 +263,7 @@ extern int target_flags;
    from 0 to just below FIRST_PSEUDO_REGISTER.
 
    All registers that the compiler knows about must be given numbers,
-   even those that are not normally considered general registers.  
+   even those that are not normally considered general registers.
 
    Reg 9 does not correspond to any hardware register, but instead
    appears in the RTL as an argument pointer prior to reload, and is
@@ -284,7 +284,7 @@ extern int target_flags;
    The latter must include the registers where values are returned
    and the register where structure-value addresses are passed.
    Aside from that, you can include as many other registers as you
-   like.  
+   like.
 
    H8 destroys r0,r1,r2,r3.  */
 
@@ -304,7 +304,7 @@ extern int target_flags;
    to hold something of mode MODE.
 
    This is ordinarily the length in words of a value of mode MODE
-   but can be less for certain modes in special long registers. 
+   but can be less for certain modes in special long registers.
 
    We pretend the MAC register is 32bits -- we don't have any data
    types on the H8 series to handle more than 32bits.  */
@@ -424,7 +424,7 @@ enum reg_class {
 #define INDEX_REG_CLASS NO_REGS
 #define BASE_REG_CLASS  GENERAL_REGS
 
-/* Get reg_class from a letter such as appears in the machine description. 
+/* Get reg_class from a letter such as appears in the machine description.
 
    'a' is the MAC register.  */
 
@@ -463,8 +463,8 @@ enum reg_class {
    0)
 
 /* Similar, but for floating constants, and defining letters G and H.
-   Here VALUE is the CONST_DOUBLE rtx itself. 
-     
+   Here VALUE is the CONST_DOUBLE rtx itself.
+
   `G' is a floating-point zero.  */
 
 #define CONST_DOUBLE_OK_FOR_LETTER_P(VALUE, C) \
@@ -486,7 +486,7 @@ enum reg_class {
 #define CLASS_MAX_NREGS(CLASS, MODE)   \
   ((GET_MODE_SIZE (MODE) + UNITS_PER_WORD - 1) / UNITS_PER_WORD)
 
-/* Any SI register-to-register move may need to be reloaded, 
+/* Any SI register-to-register move may need to be reloaded,
    so define REGISTER_MOVE_COST to be > 2 so that reload never
    shortcuts.  */
 
@@ -586,8 +586,8 @@ enum reg_class {
 /* Define how to find the value returned by a function.
    VALTYPE is the data type of the value (as a tree).
    If the precise function being called is known, FUNC is its FUNCTION_DECL;
-   otherwise, FUNC is 0. 
-   
+   otherwise, FUNC is 0.
+
    On the H8 the return value is in R0/R1.  */
 
 #define FUNCTION_VALUE(VALTYPE, FUNC) \
@@ -728,7 +728,7 @@ struct cum_arg
 #define EXIT_IGNORE_STACK 0
 
 /* Output assembler code for a block containing the constant parts
-   of a trampoline, leaving space for the variable parts.  
+   of a trampoline, leaving space for the variable parts.
 
    H8/300
              vvvv context
@@ -900,7 +900,7 @@ struct cum_arg
 
    The other macros defined here are used only in GO_IF_LEGITIMATE_ADDRESS,
    except for CONSTANT_ADDRESS_P which is actually
-   machine-independent.  
+   machine-independent.
 
    On the H8/300, a legitimate address has the form
    REG, REG+CONSTANT_ADDRESS or CONSTANT_ADDRESS.  */
@@ -930,7 +930,7 @@ struct cum_arg
    GO_IF_LEGITIMATE_ADDRESS.
 
    It is always safe for this macro to do nothing.  It exists to recognize
-   opportunities to optimize the output. 
+   opportunities to optimize the output.
 
    For the H8/300, don't do anything.  */