From: Eddie Hung Date: Wed, 19 Feb 2020 01:59:33 +0000 (-0800) Subject: Uncomment negative setup times; clamp to zero for connectivity X-Git-Tag: working-ls180~549^2~36 X-Git-Url: https://git.libre-soc.org/?a=commitdiff_plain;h=6c66030dfbcd93024f5f5bb602b9fcc58cb80a88;p=yosys.git Uncomment negative setup times; clamp to zero for connectivity --- diff --git a/techlibs/xilinx/cells_sim.v b/techlibs/xilinx/cells_sim.v index 93d080ffd..5143f87da 100644 --- a/techlibs/xilinx/cells_sim.v +++ b/techlibs/xilinx/cells_sim.v @@ -36,6 +36,9 @@ module IBUF( parameter IOSTANDARD = "default"; parameter IBUF_LOW_PWR = 0; assign O = I; + specify + (I => O) = 0; + endspecify endmodule module IBUFG( @@ -57,6 +60,9 @@ module OBUF( parameter DRIVE = 12; parameter SLEW = "SLOW"; assign O = I; + specify + (I => O) = 0; + endspecify endmodule module IOBUF ( @@ -72,6 +78,10 @@ module IOBUF ( parameter SLEW = "SLOW"; assign IO = T ? 1'bz : I; assign O = IO; + specify + (I => IO) = 0; + (IO => O) = 0; + endspecify endmodule module OBUFT ( @@ -85,14 +95,20 @@ module OBUFT ( parameter IOSTANDARD = "DEFAULT"; parameter SLEW = "SLOW"; assign O = T ? 1'bz : I; + specify + (I => O) = 0; + endspecify endmodule module BUFG( (* clkbuf_driver *) output O, input I); - assign O = I; + specify + // https://github.com/SymbiFlow/prjxray-db/blob/4bc6385ab300b1819848371f508185f57b649a0e/artix7/timings/CLK_BUFG_TOP_R.sdf#L11 + (I => O) = 96; + endspecify endmodule module BUFGCTRL( @@ -499,8 +515,8 @@ module FDRE ( endgenerate specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , posedge C &&& CE && !IS_C_INVERTED , -46); // Negative times not currently supported - //$setup(D , negedge C &&& CE && IS_C_INVERTED , -46); // Negative times not currently supported + $setup(D , posedge C &&& CE && !IS_C_INVERTED , /*-46*/ 0); // Negative times not currently supported + $setup(D , negedge C &&& CE && IS_C_INVERTED , /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE, posedge C &&& !IS_C_INVERTED, 109); $setup(CE, negedge C &&& IS_C_INVERTED, 109); @@ -529,7 +545,7 @@ module FDRE_1 ( always @(negedge C) if (R) Q <= 1'b0; else if (CE) Q <= D; specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , negedge C &&& CE, -46); // Negative times not currently supported + $setup(D , negedge C &&& CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE, negedge C, 109); // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L274 @@ -564,8 +580,8 @@ module FDSE ( endgenerate specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , posedge C &&& !IS_C_INVERTED && CE, -46); // Negative times not currently supported - //$setup(D , negedge C &&& IS_C_INVERTED && CE, -46); // Negative times not currently supported + $setup(D , posedge C &&& !IS_C_INVERTED && CE, /*-46*/ 0); // Negative times not currently supported + $setup(D , negedge C &&& IS_C_INVERTED && CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE, posedge C &&& !IS_C_INVERTED, 109); $setup(CE, negedge C &&& IS_C_INVERTED, 109); @@ -594,7 +610,7 @@ module FDSE_1 ( always @(negedge C) if (S) Q <= 1'b1; else if (CE) Q <= D; specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , negedge C &&& CE, -46); // Negative times not currently supported + $setup(D , negedge C &&& CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE, negedge C, 109); // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L274 @@ -667,8 +683,8 @@ module FDCE ( endgenerate specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , posedge C &&& !IS_C_INVERTED && CE, -46); // Negative times not currently supported - //$setup(D , negedge C &&& IS_C_INVERTED && CE, -46); // Negative times not currently supported + $setup(D , posedge C &&& !IS_C_INVERTED && CE, /*-46*/ 0); // Negative times not currently supported + $setup(D , negedge C &&& IS_C_INVERTED && CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE , posedge C &&& !IS_C_INVERTED, 109); $setup(CE , negedge C &&& IS_C_INVERTED, 109); @@ -697,7 +713,7 @@ module FDCE_1 ( always @(negedge C, posedge CLR) if (CLR) Q <= 1'b0; else if (CE) Q <= D; specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , negedge C &&& CE, -46); // Negative times not currently supported + $setup(D , negedge C &&& CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE , negedge C, 109); // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L274 @@ -734,8 +750,8 @@ module FDPE ( endgenerate specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , posedge C &&& !IS_C_INVERTED && CE, -46); // Negative times not currently supported - //$setup(D , negedge C &&& IS_C_INVERTED && CE, -46); // Negative times not currently supported + $setup(D , posedge C &&& !IS_C_INVERTED && CE, /*-46*/ 0); // Negative times not currently supported + $setup(D , negedge C &&& IS_C_INVERTED && CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE , posedge C &&& !IS_C_INVERTED, 109); $setup(CE , negedge C &&& IS_C_INVERTED, 109); @@ -764,7 +780,7 @@ module FDPE_1 ( always @(negedge C, posedge PRE) if (PRE) Q <= 1'b1; else if (CE) Q <= D; specify // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L249 - //$setup(D , negedge C &&& CE, -46); // Negative times not currently supported + $setup(D , negedge C &&& CE, /*-46*/ 0); // Negative times not currently supported // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L248 $setup(CE , negedge C, 109); // https://github.com/SymbiFlow/prjxray-db/blob/23c8b0851f979f0799318eaca90174413a46b257/artix7/timings/slicel.sdf#L274